Usage
newDCLink(
name,
commodity,
from,
to,
resistance = NA_real_,
trade = data.frame(),
bidirectional = TRUE,
...
)Arguments
- name
character, name of the object, used in sets.
- commodity
character, the transmitted commodity (normally electricity).
- from, to
character, the two endpoint regions of the line.
- resistance
numeric, series resistance
r. Recorded but not used for losses – losses are the fixed fractionteff.- trade
data.frame of further per-route parameters (
ava.*,af.*,teff), applied to both directions unless it namessrc/dst.- bidirectional
logical,
TRUE(default) declares both directions andFALSEonlyfrom->to. Note both directions still share ONE capacity.- ...
further arguments passed to
newTrade().
Details
A DC link's flow is a control decision, which is what a transport model
represents natively, so this constructor adds no physics: it exists so that
a network reads as what it is, with AC lines built by newACLine() and DC
links by this.
A DC link carries NO reactance and is therefore never part of the KVL cycle
basis, however the model is interpolated. resistance is recorded for
round-tripping only; losses are the fixed fraction teff.
See also
Other class trade:
lossTranches(),
newACLine()
Examples
dc <- newDCLink("K_W1_C1", commodity = "ELC", from = "W1", to = "C1",
resistance = 0.001)
dc@routes
#> src dst
#> 1 W1 C1
#> 2 C1 W1
# a one-way link declares a single route
newDCLink("K_ONE_WAY", commodity = "ELC", from = "W1", to = "C1",
bidirectional = FALSE)@routes
#> src dst
#> 1 W1 C1